Question: How does a Pumptec work?

Pumptec is a microcomputer-based device that monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks, and abnormal line voltage conditions. Pumptec interrupts power to the motor whenever the load drops quickly or below a preset level.

What does underload mean on Pumptec?

A solid yellow light with no flicker indicates a dry well (underload). This is caused by the load of the motor going below the underload adjustment knob. Note: In both conditions above, the Pumptec will wait until the reset time-out period has ended before attempting to restart the motor.

How do you reset a Pumptec?

Remove the Pumptec-Plus cover by removing the cover screw and sliding the cover up. Place cover in a safe location. Set the automatic timer switch to the desired reset time. This will reset the time after an underload trip condition (dry well condition) has occurred until the Pumptec-Plus will try to restart the motor.

How do I reset my Franklin Electric Pumptec?

The unit must be manually reset by removing power for 10 seconds. (If you have a Pumptec remote control, this will be indicated by overload in the Pumptec Fault History.) Voltage Indicator Light When the voltage light is solid, an under voltage condition has been detected.

What is a well pump protector?

The water well pump protection switch monitors motor load and power line conditions to provide protection against drywell conditions, waterlogged tanks, and abnormal line voltage conditions. This Pumptec well pump protection device interrupts power to the motor whenever the load drops quickly or below a preset level.

You might be interested:  Quick Answer: How do you store collectible Barbie dolls?

Why does my Pumptec keeps tripping?

When Pumptec detects that the motor load has dropped below a preset level for over 4 seconds, it will interrupt power to the motor and display the tripped condition light. To reset Pumptec manually, turn off the power supply for 5 seconds, and then turn it back on.

How do you calibrate a pump saver?

The PumpSaver®Plus can also be calibrated while the pump is running. Turn the RESTART DELAY/ CALIBRATION knob to CAL. while pumping. Wait for the pump to turn off (approximately 10 seconds), then adjust the RESTART DELAY/ CALIBRATION knob to the desired setting.